[:en]EP1100 720W 1440W modifed sine wave inverter applied to TV, stereos, laptop and desktop computers and other home appliance.It will automatically transfer to inverter and provide power when AC supply is interrupted unexpectedly.
LCD/LED Display Information
1. LCD DISPLAY
2. FAULT LED
3. INVERTER MODE LED
4. MAINS MODE LED
5. POWER ON/OFF
Figure 1 Back Panel Information
6. DC Input Connector (Battery Terminal)
7. Input Voltage Range Selector: Input voltage range is defined in specification chapter, and output voltage is the same as input voltage in ‘mains’ mode
8. AC Input
9. Output Receptacle(s)
10. Charge Current Selector: 10A/20A adjustable
Inverter Connection
- Charge current 10A/20A adjustable.
- Double layers PCB board.
- Compact size for convenient use.
- Three-steps intelligent charge controller.
- With Battery Reverse Protection Function (Optional).
- Home use, for DVD, TV, Lights, and Fans.
- With battery cable 10AWG 60cm
MODEL | EP11-1200 | EP11-1800 | EP11-2400 | |||||
---|---|---|---|---|---|---|---|---|
Default Battery System Voltage | 12VDC | 12VDC | 24VDC | |||||
INVERTER OUTPUT | Rated Power | 1200VA/720W | 1800VA/1000W | 2400VA/1440W | ||||
Waveform | Modifided Sine-wave | |||||||
Nominal Output Voltage RMS | 230V | |||||||
Output Voltage Regulation | +10/-18% | |||||||
Output Frequency | 50Hz/60Hz +/-0.5 Hz | |||||||
Inverter Efficiency(Peak) | >80% | |||||||
Line Mode Efficiency | >95% | |||||||
Power Factor | 0.6 | |||||||
Typical Transfer Time | Typical 15~20ms 40ms max | |||||||
AC INPUT | Voltage | 230VAC | ||||||
Selectable Voltage Range | Narrow | 170~280VAC | ||||||
Wide | 90~280VAC | |||||||
Frequency Range | 50Hz/60Hz (Auto sensing) | |||||||
BATTERY | Nominal Input Voltage | 12VDC | 24VDC | |||||
Minimum Start Voltage | 10.5VDC | 21.0VDC | ||||||
Low Battery Alarm | 10.5VDC+/-0.3V | 21.0VDC+/-0.3V | ||||||
Low Battery Cutoff | 10.0VDC+/-0.3V | 20.0VDC+/-0.3V | ||||||
High Voltage Alarm | 16.0VDC+/-0.3V | 32.0VDC+/-0.3V | ||||||
High Battery Voltage Recover | 15.0VDC+/-0.3V | 30.0VDC+/-0.3V | ||||||
CHARGER | Charger Voltage (Vbat<12.5V) | 14.4VDC+/-0.4V | 28.8VDC+/-0.4V | |||||
Charger Voltage (Vbat>12.5V) | 13.7VDC+/-0.2V | 27.4VDC+/-0.2V | ||||||
Charging Current 10A | 10A±2A | |||||||
Charging Current 20A | 20A±2A | |||||||
Overcharge Protection S.D. | 16VDC ±0.4A | 32VDC ±0.8A | ||||||
BYPASS & PROTECTION |
Nominal Input Frequency | 50Hz or 60Hz | ||||||
Overload Protection (SMPS Load) | FUSE | |||||||
Output Short Circuit Protection | FUSE | |||||||
Bypass Fuse Rating | 10A | |||||||
Max Bypass Current | 10Amp | |||||||
MECHANICAL SPECIFICATIONS | Dimensions (W*H*D) | 253*267*90mm | ||||||
Net Weight (kg) | 2.3 | 2.5 | ||||||
Shipping Dimensions(W*H*D) | 319*328*123mm | |||||||
Shipping Weight (kg) | 2.9 | 3.1 | ||||||
OTHER | Operation Temperature Range | 0°C to 40°C | ||||||
Audible Noise | 60dB MAX | |||||||
Display | LED+LCD | |||||||
Standard Warranty | 1 year | |||||||
Loading(20GP/40GP/40HQ) | 1800pcs / 3600pcs / 4200pcs |
Approximate Back-Up Time Table
Power Rate(w) | backup time(H) @1*100Ah |
backup time(H) @2*100Ah |
backup time(H) @4*100Ah |
backup time(H) @4*200Ah |
||||
---|---|---|---|---|---|---|---|---|
720 | 1.4 | 2.8 | 5.6 | 11.2 | ||||
1000 | 0.9 | 1.9 | 3.8 | 7.5 | ||||
1400 | 1.4 | 2.8 | 5.6 |
[:]