[:ru]NY 300w-1Kw Sine Wave Inverter With LCD Display[:en]NY 300w-1Kw Sine Wave Inverter With LCD Display[:]

Категории: 

[:ru]It can power most common electrical appliances such as lights, TV, cash registers, Refrigerator, Fan, Air conditioner, Induction cooker, Micro-wave oven, washing machines, computers, and power tools, Etc.

  • Pure sine-wave output;
  • 25A battery charge current;
  • Superior performance from CPU control technology;
  • Fast Action AC Synchronized Transfer Switch
  • Wide range of input voltage, accurate output, AVR function;
  • Inner-Equipped protection for over-load, short-circuit, over-voltage, low-voltage, over- heating, etc.
  • Easy to check with inverter condition with concise LCD indication. Generator compatibly and external battery connection achievable.
  • Intelligent battery management with protection against over-charged and over-discharged etc.
  • Special charging system design for better protection of battery life.
  • Compatible with generators and suitable for harsh environment where power voltage is extremely unstable.
  • With standard on-line structure (three ports) and can be used as UPS.
  • Extremely low return noise and no disturbance to talking quality.
Model No. NY300 NY500 NY600 NY800 NY1000
  Output Power Continuous 300W 500W 600W 800W 1000W
1. Input Section
  Input Nominal Voltage 110Vac or 230Vac
  Input Voltage Range 60V~135Vac or 120V~275Vac
  Line Low Transfer 60Vac ± 2% or 120Vac ± 2%
  Line Low Return 65Vac ± 2% or 130Vac ± 2%
  Line High Transfer 145Vac ± 2% or 285Vac ± 2%
  Line High Return 130Vac ± 2% or 260Vac ± 2%
  Input Frequency 50Hz / 60Hz (45Hz~70Hz)
2. Output Section
  Output Voltage 110Vac / 120Vac or 220Vac / 230Vac / 240Vac
  Waveform Pure Sine Wave
  Voltage Regulation (Batt. Mode) < 3% RMS for entire battery voltage range
  Output Frequency 50Hz or 60Hz ± 0.1Hz
  Efficiency > 85%
  Maximum Load Up to short circuit
  Asymmetrical Load Max. Up to nominal output power
  Overload and Short Circuit Protection Automatic disconnection
  Overheating Temperature Protection Acoustic warning before shut-off.
  Power Factor 0.8
3. Battery Section
  Voltage Range 12VDC (10.5~14.3VDC)
  Backup Time (at full load) Long time available
  Input Frequency Range 45~70Hz
Max. Charging Current 25A
DC voltage 12V
4. Display
  LCD Display INVERTER status, I/P&O/P Voltage Frequency, Load%,
Battery Voltage & %, Temperature, Mode
  LED Display Normal (Green), Warning (Yellow), Fault (Red)
5. Audible Alarm
  Battery Mode Beeping every 4 seconds
  Low Battery Beeping every second
  Overload Beeping twice per second
  Temperature Compensation (Option) 3mV / °C cell
6. General date
  AC By Pass Time (UPS Mode) 5ms
  Operation Temperature -20 °C to +55 °C
  Audible Noise Less than 55dBA (at 1M)
  Relative Humidity 0-95% non-condensing

[:en]It can power most common electrical appliances such as lights, TV, cash registers, Refrigerator, Fan, Air conditioner, Induction cooker, Micro-wave oven, washing machines, computers, and power tools, Etc.

  • Pure sine-wave output;
  • 25A battery charge current;
  • Superior performance from CPU control technology;
  • Fast Action AC Synchronized Transfer Switch
  • Wide range of input voltage, accurate output, AVR function;
  • Inner-Equipped protection for over-load, short-circuit, over-voltage, low-voltage, over- heating, etc.
  • Easy to check with inverter condition with concise LCD indication. Generator compatibly and external battery connection achievable.
  • Intelligent battery management with protection against over-charged and over-discharged etc.
  • Special charging system design for better protection of battery life.
  • Compatible with generators and suitable for harsh environment where power voltage is extremely unstable.
  • With standard on-line structure (three ports) and can be used as UPS.
  • Extremely low return noise and no disturbance to talking quality.
Model No. NY300 NY500 NY600 NY800 NY1000
  Output Power Continuous 300W 500W 600W 800W 1000W
1. Input Section
  Input Nominal Voltage 110Vac or 230Vac
  Input Voltage Range 60V~135Vac or 120V~275Vac
  Line Low Transfer 60Vac ± 2% or 120Vac ± 2%
  Line Low Return 65Vac ± 2% or 130Vac ± 2%
  Line High Transfer 145Vac ± 2% or 285Vac ± 2%
  Line High Return 130Vac ± 2% or 260Vac ± 2%
  Input Frequency 50Hz / 60Hz (45Hz~70Hz)
2. Output Section
  Output Voltage 110Vac / 120Vac or 220Vac / 230Vac / 240Vac
  Waveform Pure Sine Wave
  Voltage Regulation (Batt. Mode) < 3% RMS for entire battery voltage range
  Output Frequency 50Hz or 60Hz ± 0.1Hz
  Efficiency > 85%
  Maximum Load Up to short circuit
  Asymmetrical Load Max. Up to nominal output power
  Overload and Short Circuit Protection Automatic disconnection
  Overheating Temperature Protection Acoustic warning before shut-off.
  Power Factor 0.8
3. Battery Section
  Voltage Range 12VDC (10.5~14.3VDC)
  Backup Time (at full load) Long time available
  Input Frequency Range 45~70Hz
Max. Charging Current 25A
DC voltage 12V
4. Display
  LCD Display INVERTER status, I/P&O/P Voltage Frequency, Load%,
Battery Voltage & %, Temperature, Mode
  LED Display Normal (Green), Warning (Yellow), Fault (Red)
5. Audible Alarm
  Battery Mode Beeping every 4 seconds
  Low Battery Beeping every second
  Overload Beeping twice per second
  Temperature Compensation (Option) 3mV / °C cell
6. General date
  AC By Pass Time (UPS Mode) 5ms
  Operation Temperature -20 °C to +55 °C
  Audible Noise Less than 55dBA (at 1M)
  Relative Humidity 0-95% non-condensing

[:]

Комментарии закрыты.