[:ru]It can power most common electrical appliances such as lights, TV, cash registers, Refrigerator, Fan, Air conditioner, Induction cooker, Micro-wave oven, washing machines, computers, and power tools, Etc.
- Pure sine-wave output;
- 25A battery charge current;
- Superior performance from CPU control technology;
- Fast Action AC Synchronized Transfer Switch
- Wide range of input voltage, accurate output, AVR function;
- Inner-Equipped protection for over-load, short-circuit, over-voltage, low-voltage, over- heating, etc.
- Easy to check with inverter condition with concise LCD indication. Generator compatibly and external battery connection achievable.
- Intelligent battery management with protection against over-charged and over-discharged etc.
- Special charging system design for better protection of battery life.
- Compatible with generators and suitable for harsh environment where power voltage is extremely unstable.
- With standard on-line structure (three ports) and can be used as UPS.
- Extremely low return noise and no disturbance to talking quality.
Model No. | NY300 | NY500 | NY600 | NY800 | NY1000 |
Output Power Continuous | 300W | 500W | 600W | 800W | 1000W |
1. Input Section | |||||
Input Nominal Voltage | 110Vac or 230Vac | ||||
Input Voltage Range | 60V~135Vac or 120V~275Vac | ||||
Line Low Transfer | 60Vac ± 2% or 120Vac ± 2% | ||||
Line Low Return | 65Vac ± 2% or 130Vac ± 2% | ||||
Line High Transfer | 145Vac ± 2% or 285Vac ± 2% | ||||
Line High Return | 130Vac ± 2% or 260Vac ± 2% | ||||
Input Frequency | 50Hz / 60Hz (45Hz~70Hz) | ||||
2. Output Section | |||||
Output Voltage | 110Vac / 120Vac or 220Vac / 230Vac / 240Vac | ||||
Waveform | Pure Sine Wave | ||||
Voltage Regulation (Batt. Mode) | < 3% RMS for entire battery voltage range | ||||
Output Frequency | 50Hz or 60Hz ± 0.1Hz | ||||
Efficiency | > 85% | ||||
Maximum Load | Up to short circuit | ||||
Asymmetrical Load Max. | Up to nominal output power | ||||
Overload and Short Circuit Protection | Automatic disconnection | ||||
Overheating Temperature Protection | Acoustic warning before shut-off. | ||||
Power Factor | 0.8 | ||||
3. Battery Section | |||||
Voltage Range | 12VDC (10.5~14.3VDC) | ||||
Backup Time (at full load) | Long time available | ||||
Input Frequency Range | 45~70Hz | ||||
Max. Charging Current | 25A | ||||
DC voltage | 12V | ||||
4. Display | |||||
LCD Display | INVERTER status, I/P&O/P Voltage Frequency, Load%, | ||||
Battery Voltage & %, Temperature, Mode | |||||
LED Display | Normal (Green), Warning (Yellow), Fault (Red) | ||||
5. Audible Alarm | |||||
Battery Mode | Beeping every 4 seconds | ||||
Low Battery | Beeping every second | ||||
Overload | Beeping twice per second | ||||
Temperature Compensation (Option) | 3mV / °C cell | ||||
6. General date | |||||
AC By Pass Time (UPS Mode) | 5ms | ||||
Operation Temperature | -20 °C to +55 °C | ||||
Audible Noise | Less than 55dBA (at 1M) | ||||
Relative Humidity | 0-95% non-condensing |
[:en]It can power most common electrical appliances such as lights, TV, cash registers, Refrigerator, Fan, Air conditioner, Induction cooker, Micro-wave oven, washing machines, computers, and power tools, Etc.
- Pure sine-wave output;
- 25A battery charge current;
- Superior performance from CPU control technology;
- Fast Action AC Synchronized Transfer Switch
- Wide range of input voltage, accurate output, AVR function;
- Inner-Equipped protection for over-load, short-circuit, over-voltage, low-voltage, over- heating, etc.
- Easy to check with inverter condition with concise LCD indication. Generator compatibly and external battery connection achievable.
- Intelligent battery management with protection against over-charged and over-discharged etc.
- Special charging system design for better protection of battery life.
- Compatible with generators and suitable for harsh environment where power voltage is extremely unstable.
- With standard on-line structure (three ports) and can be used as UPS.
- Extremely low return noise and no disturbance to talking quality.
Model No. | NY300 | NY500 | NY600 | NY800 | NY1000 |
Output Power Continuous | 300W | 500W | 600W | 800W | 1000W |
1. Input Section | |||||
Input Nominal Voltage | 110Vac or 230Vac | ||||
Input Voltage Range | 60V~135Vac or 120V~275Vac | ||||
Line Low Transfer | 60Vac ± 2% or 120Vac ± 2% | ||||
Line Low Return | 65Vac ± 2% or 130Vac ± 2% | ||||
Line High Transfer | 145Vac ± 2% or 285Vac ± 2% | ||||
Line High Return | 130Vac ± 2% or 260Vac ± 2% | ||||
Input Frequency | 50Hz / 60Hz (45Hz~70Hz) | ||||
2. Output Section | |||||
Output Voltage | 110Vac / 120Vac or 220Vac / 230Vac / 240Vac | ||||
Waveform | Pure Sine Wave | ||||
Voltage Regulation (Batt. Mode) | < 3% RMS for entire battery voltage range | ||||
Output Frequency | 50Hz or 60Hz ± 0.1Hz | ||||
Efficiency | > 85% | ||||
Maximum Load | Up to short circuit | ||||
Asymmetrical Load Max. | Up to nominal output power | ||||
Overload and Short Circuit Protection | Automatic disconnection | ||||
Overheating Temperature Protection | Acoustic warning before shut-off. | ||||
Power Factor | 0.8 | ||||
3. Battery Section | |||||
Voltage Range | 12VDC (10.5~14.3VDC) | ||||
Backup Time (at full load) | Long time available | ||||
Input Frequency Range | 45~70Hz | ||||
Max. Charging Current | 25A | ||||
DC voltage | 12V | ||||
4. Display | |||||
LCD Display | INVERTER status, I/P&O/P Voltage Frequency, Load%, | ||||
Battery Voltage & %, Temperature, Mode | |||||
LED Display | Normal (Green), Warning (Yellow), Fault (Red) | ||||
5. Audible Alarm | |||||
Battery Mode | Beeping every 4 seconds | ||||
Low Battery | Beeping every second | ||||
Overload | Beeping twice per second | ||||
Temperature Compensation (Option) | 3mV / °C cell | ||||
6. General date | |||||
AC By Pass Time (UPS Mode) | 5ms | ||||
Operation Temperature | -20 °C to +55 °C | ||||
Audible Noise | Less than 55dBA (at 1M) | ||||
Relative Humidity | 0-95% non-condensing |
[:]